Gas transmitter - ADOS LCTR 903

The gas transmitter ADOS LCTR 903 is suitable for the detection of combustible gases, for example hydrogen, methane (natural gas) or propane?/?butane (LPG) in air in the LEL region.

Two transmitter versions with different output signals are available:
- 3-wire 4–20 mA
- 4-wire LON? (LCTR 904)

Three measuring principles are available:
- VQ
- TGS
- IR
  • 技術(shù)參數(shù)
  • 產(chǎn)品特點(diǎn)
  • 應(yīng)用領(lǐng)域
  • 資料下載

Technical data
 

Type TGS VQ IR
Measurement method: Semiconductor Heat reduction Infrared
Measurement range: ppm ranges
to 100 % LEL
ppm ranges
to 100 % LEL
0–100 % LEL
CH4, C3H8, C2H2
0–100 Vol % CH4
0–1, 2, 3, 4, 5 Vol % CO2
Percentage error of f.s.d.: ± 5 % ± 5 % ± 3 %
Linearity: < 15 % of f.s.d. < 3 % of f.s.d. < 3 % of f.s.d.
Temperature range: -20 °C to +45 °C -20 °C to +45 °C -20 °C to +45 °C
Temperature effect: 5 % 2 % 8 %
Response time (t90): approx. 20 sec. approx. 20 sec. < 30 sec.
Pressure effect: 1 % 1 % 1 %
Mounting position: optional optional optional
Application: Poisonous, combustible and explosive gases in the LEL region Poisonous, combustible and explosive gases in the LEL region Poisonous, combustible and explosive gases in the LEL region
Expected operation time
for sensor:
> 2 years > 2 years approx. 5 years
Supply voltage: 15V - 30V 15V - 30V 15V - 30V
Interface: 4–20 mA three-wire or
LON® fourwire techniques
(LCTR 404), galvanically
isolated, data transmission 78 kbps
4–20 mA three-wire or
LON® fourwire techniques
(LCTR 404), galvanically
isolated, data transmission 78 kbps
4–20 mA three-wire or
LON® fourwire techniques
(LCTR 404), galvanically
isolated, data transmission 78 kbps
Protection class: IP 30 IP 30 IP 30
Dimensions
(height x diameter):
80 x 80 mm 80 x 80 mm 80 x 80 mm
Weight: 500 g 500 g 500 g

The TGS sensor 
The TGS sensor contains a semiconductor sensor,
which is constructed on SnO2 -sintered N-substrate.
When combustible or reducing gases are absorbed by the surface of the sensor, the concentration of the test gas is determined by the change in conductivity.

 

1 = Circuit voltage
2 = Heating voltage
3 = Load resistor



The VQ sensor 
The head of the VQ sensor functions on the principle of heat ­reaction. When combustible or reducing gases or ­vapours come in contact with the measuring element, they are subjected to catalytic ­combustion, which ­causes a rise in temperature. This rise causes a change in the resistance of the measuring element which is used as a measure of the component of gas being tested. The inert element is for compensating the temperature and conduc­tivity of the test gas.



1 = Catalyzer pellistor
2 = Electric connections
3 = Inert pellistor
4 = Diffusion filter


The IR sensor
The test gas flows through a measurement chamber that incorporates an IR radiating source and a two-channel infrared detector. The intensity of the infrared radiation is reduced as it passes through the gas molecules. The concentration of the gas can then be calculated by the magnitude of the reduction in intensity. Since only absorption of the wavelength (A) specific to the gas under test in relation to the wavelength (B) not absorbed by a test gas is considered, interference due to dust, ageing etc., is almost fully compensated.


1 = Infrared-radiation source
2 = Test gas
3 = Diffusion filter
4 = Infrared-detector
5 = Measurement chamber
 
  • Gas fired boiler systems
  • Gas distribution station
  • Gas transfer station
  • Battery charging station